How do I choose the phase type and connection?
| Model | Phase | Connection | Cloud access | Supporting equipment | Enterprise access |
|---|---|---|---|---|---|
| M1470(M1) | Three-phase | RS485 / AU470 / 4G Cat1, by configuration | Central cloud access on versions with 4G | 3 external CTs; separate contactor for switching | RS485 → AG-2701X → enterprise Ethernet; protocol and point-map review required, joint physical testing pending. |
| M2470(M2) | Single-phase | AU470 + RS485 | Central cloud access through an M1 master | Compatible master; communication accessories to suit the site | RS485 + AG271X evaluation; confirm protocol and version |
| M3 | Single-phase | 4G Cat1 + RS485 | Direct cloud access through 4G | SIM and data plan; no separate gateway | RS485 + AG271X evaluation; confirm protocol and version |
| M4 | Single-phase | RS485 wired | Central cloud access through a compatible master | M1 / M2 / M3 with the required master capability | RS485 → AG-2701X → enterprise Ethernet; protocol and point-map review required, joint physical testing pending. |
How do M2 and M4 differ?
M2 supports AU470 and RS485 networking, with an RS485/AU470 transparent gateway function. M4 is an RS485 wired slave node. Both need a master device to collect data for cloud access.
Does M3 need a gateway?
M3 has built-in 4G Cat1 for direct cloud access. Check local cellular bands, signal at the installation point and the SIM data plan.
What should I prepare before asking for a quote?
Provide the country or region, number of rooms or circuits, phase type and cabling conditions. For existing meters, distribution boards or management systems, include models, photos or interface requirements.
Are prepayment and remote switching available?
The M2–M4 product designs include local balance storage, offline deduction and relay control. These functions need compatible platform, master and firmware versions. M1 uses its control output to drive an external three-phase contactor, which switches the main circuit.
The material shown here does not mean that the complete device and payment workflow have passed acceptance testing. Payment channels, tariffs and billing rules are agreed per project.
How are installation and support arranged?
The quotation defines responsibility for site work, commissioning, spares, repairs and remote support. Electrical wiring must follow the version-specific wiring documents and be completed by personnel qualified locally.
How should I use the images and catalogue?
Product pages link to the full catalogue in Simplified Chinese. Website product illustrations follow the selected language. Display readings in illustrations are not rated specifications. Follow the wiring documents for the supplied version.
Enterprise electricity data and system integration
Connecting site meters to an existing enterprise system? The RS485 variant of M1, M4 and AG-2701X form a wired collection setup for factories, buildings, retail chains and other projects.