Room metering and commercial circuit monitoring

DCZD electricity meters

Room metering.
Commercial circuit data.

Record electricity use for each room or circuit. Connect grouped meters through RS485 or AU470, or use 4G for separate locations.

M3 single-phase 4G meter with an internal antenna and one RS485 port
M3 single-phase 4G meter · Product illustration

Choose a connection for your site

Grouped rooms, accessible cabling

Connect apartment or dormitory meters to an RS485 bus for central collection. M4 is the wired submeter option.

Apartment and dormitory setups →

Retrofits with limited cable access

M2 connects to a master through AU470 or RS485. Test wireless coverage at the installation site before choosing AU470.

View M2 →

Separate locations, individual connections

M3 connects directly through 4G Cat1 without a separate gateway. Use it for scattered rental properties or individual shops.

View M3 →

The M1–M4 meter range

M1 meters three-phase circuits. M2, M3 and M4 meter single-phase rooms or branches. Compare connections and supporting equipment below.

Models and connections
ModelPhaseConnectionCloud accessSupporting equipmentEnterprise access
M1470(M1)Three-phaseRS485 / AU470 / 4G Cat1, by configurationCentral cloud access on versions with 4G3 external CTs; separate contactor for switchingRS485 → AG-2701X → enterprise Ethernet; protocol and point-map review required, joint physical testing pending.
M2470(M2)Single-phaseAU470 + RS485Central cloud access through an M1 masterCompatible master; communication accessories to suit the siteRS485 + AG271X evaluation; confirm protocol and version
M3Single-phase4G Cat1 + RS485Direct cloud access through 4GSIM and data plan; no separate gatewayRS485 + AG271X evaluation; confirm protocol and version
M4Single-phaseRS485 wiredCentral cloud access through a compatible masterM1 / M2 / M3 with the required master capabilityRS485 → AG-2701X → enterprise Ethernet; protocol and point-map review required, joint physical testing pending.

Start with these three details

Tell us the installation country or region, the number of rooms or circuits, and whether communication cables can be installed. If you already use meters or a management system, include their models and interface requirements.

Describe your site

Enterprise electricity data and system integration

Connecting site meters to an existing enterprise system? The RS485 variant of M1, M4 and AG-2701X form a wired collection setup for factories, buildings, retail chains and other projects.

Explore the enterprise proposal →

Add AC-2705X for equipment status and control

AC-2705X field I/O converter with DCZD branding

Extend the M1, M4 and AG-2701X collection setup with AC-2705X where needed: four isolated inputs collect status and eight relay outputs connect field controls. Confirm signals, loads and feedback before configuring equipment and software.

View AC-2705X Discuss the control extension