{"id":145,"date":"2026-10-21T10:35:04","date_gmt":"2026-10-21T02:35:04","guid":{"rendered":"https:\/\/site.dcsmartmeter.com\/enterprise\/products\/"},"modified":"2026-10-21T11:57:30","modified_gmt":"2026-10-21T03:57:30","slug":"products","status":"publish","type":"page","link":"https:\/\/site.dcsmartmeter.com\/en\/enterprise\/products\/","title":{"rendered":"Enterprise equipment: base collection and control extension"},"content":{"rendered":"<p><\/p>\n<p>These three products form the wired enterprise proposal. M1 and M4 meter the circuits; AG-2701X provides Ethernet access. Quantities follow the circuit plan.<\/p>\n<div class=\"dcai-grid\">\n<article>\n<h3>M1 \u00b7 Three-phase circuits<\/h3>\n<p>Meter incomers and three-phase equipment with three external CTs. This proposal uses the RS485 variant.<\/p>\n<\/article>\n<article>\n<h3>M4 \u00b7 Single-phase branches<\/h3>\n<p>Meter lighting, sockets, rooms and single-phase equipment through one RS485 interface.<\/p>\n<\/article>\n<article>\n<h3>AG-2701X \u00b7 Enterprise Ethernet<\/h3>\n<p>Connect two RS485 channels to Ethernet using raw TCP or the Modbus function 03\/04 read path.<\/p>\n<\/article>\n<\/div>\n<section class=\"dcai-panel dcai-gateway\"><span class=\"dcai-eyebrow\">AG-2701X<\/span><h2>M1 + M4 + AG-2701X: enterprise metering<\/h2><div class=\"dcai-grid\"><figure><img decoding=\"async\" src=\"https:\/\/site.dcsmartmeter.com\/wp-content\/themes\/dcai-storefront\/assets\/ag2701x-dczd.png\" width=\"280\" height=\"280\" loading=\"lazy\" alt=\"AG-2701X product rendering with DCZD branding\"><\/figure><div><p>DIN rail dual-RS485 Ethernet gateway with one RJ45, two 3-pin RS485 channels and a nominal 82 \u00d7 54 \u00d7 32 mm enclosure. Combine with M1 and M4; see the handbook for functions and physical-test limits.<\/p><a class=\"dcai-button\" href=\"https:\/\/site.dcsmartmeter.com\/en\/ag271x\/\">Explore the three-product setup<\/a><p><a href=\"\/wp-content\/uploads\/dcai-brand\/DCZD_AG2701X_Product_Manual_zh-Hant_v1.pdf\">AG-2701X handbook (Traditional Chinese DCZD brand edition PDF)<\/a><\/p><\/div><\/div><\/section>\n<section class=\"dcai-section\">\n<h2>Meter specifications<\/h2>\n<p><div class=\"dcai-table\"><table><caption>Models and connections<\/caption><thead><tr><th>Model<\/th><th>Phase<\/th><th>Connection<\/th><th>Cloud access<\/th><th>Supporting equipment<\/th><th>Enterprise access<\/th><\/tr><\/thead><tbody><tr><th><a href=\"https:\/\/site.dcsmartmeter.com\/en\/product\/m1\/\">M1470\uff08M1\uff09<\/a><\/th><td>Three-phase<\/td><td>RS485 \/ AU470 \/ 4G Cat1, by configuration<\/td><td>Central cloud access on versions with 4G<\/td><td>3 external CTs; separate contactor for switching<\/td><td>RS485 \u2192 AG-2701X \u2192 enterprise Ethernet; protocol and point-map review required, joint physical testing pending.<\/td><\/tr><tr><th><a href=\"https:\/\/site.dcsmartmeter.com\/en\/product\/m4\/\">M4<\/a><\/th><td>Single-phase<\/td><td>RS485 wired<\/td><td>Central cloud access through a compatible master<\/td><td>M1 \/ M2 \/ M3 with the required master capability<\/td><td>RS485 \u2192 AG-2701X \u2192 enterprise Ethernet; protocol and point-map review required, joint physical testing pending.<\/td><\/tr><\/tbody><\/table><\/div><\/section>\n<section class=\"dcai-section\">\n<h2>Industry handbook<\/h2>\n<p>System structure, product roles, ten industries, integration conditions and acceptance checks.<\/p>\n<p><a class=\"dcai-button\" href=\"\/wp-content\/uploads\/dcai-brand\/DCZD_M1_M4_AG2701X_Industry_Handbook_v1.pdf\">Download industry handbook (Simplified Chinese PDF)<\/a><\/section>\n<div class=\"woocommerce columns-2 \"><ul class=\"products columns-2\">\n<li class=\"product type-product post-23 status-publish first instock product_cat-multiroom product_cat-commercial has-post-thumbnail shipping-taxable product-type-external\">\n\t<a href=\"https:\/\/site.dcsmartmeter.com\/en\/product\/m1\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/site.dcsmartmeter.com\/wp-content\/themes\/dcai-storefront\/assets\/M1-en.svg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"M1470 (M1) \u00b7 Three-phase smart meter\" \/><h2 class=\"woocommerce-loop-product__title\">M1470 (M1) \u00b7 Three-phase smart meter<\/h2>\n<\/a><a href=\"https:\/\/site.dcsmartmeter.com\/en\/inquiry\/?model=M1&#038;source=products&#038;purpose\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_23\" data-quantity=\"1\" class=\"button product_type_external\" data-product_id=\"23\" data-product_sku=\"M1\" aria-label=\"Ask about this meter\" rel=\"nofollow\">Ask about this meter<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_23\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<li class=\"product type-product post-29 status-publish last instock product_cat-multiroom product_cat-commercial has-post-thumbnail shipping-taxable product-type-external\">\n\t<a href=\"https:\/\/site.dcsmartmeter.com\/en\/product\/m4\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/site.dcsmartmeter.com\/wp-content\/themes\/dcai-storefront\/assets\/M4-en.svg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"M4 \u00b7 Single-phase RS485 wired meter\" \/><h2 class=\"woocommerce-loop-product__title\">M4 \u00b7 Single-phase RS485 wired meter<\/h2>\n<\/a><a href=\"https:\/\/site.dcsmartmeter.com\/en\/inquiry\/?model=M4&#038;source=products&#038;purpose\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_29\" data-quantity=\"1\" class=\"button product_type_external\" data-product_id=\"29\" data-product_sku=\"M4\" aria-label=\"Ask about this meter\" rel=\"nofollow\">Ask about this meter<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_29\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n<\/li>\n<\/ul>\n<\/div>\n<section class=\"dcai-section\">\n<h2>Add AC-2705X for equipment status and control<\/h2>\n<div class=\"dcai-industry-grid\">\n<figure><img decoding=\"async\" src=\"\/wp-content\/uploads\/dcai-brand\/enterprise-four-v2\/assets\/ac2705x-dczd.png\" width=\"360\" height=\"360\" loading=\"lazy\" style=\"max-width:100%;width:360px;height:auto\" alt=\"AC-2705X field I\/O converter with DCZD branding\"><\/figure>\n<div>\n<p>Extend the M1, M4 and AG-2701X collection setup with AC-2705X where needed: four isolated inputs collect status and eight relay outputs connect field controls. Confirm signals, loads and feedback before configuring equipment and software.<\/p>\n<p><a class=\"dcai-button\" href=\"https:\/\/site.dcsmartmeter.com\/en\/ac2705x\/\">View AC-2705X<\/a> <a class=\"dcai-button\" href=\"https:\/\/site.dcsmartmeter.com\/en\/inquiry\/?purpose=enterprise&#038;solution=ag271x-meter-io&#038;source=ac2705x\">Discuss the control extension<\/a><\/div>\n<\/div>\n<\/section>\n<p><a class=\"dcai-button\" href=\"\/wp-content\/uploads\/dcai-brand\/enterprise-four-v2\/industry\/DCZD_Enterprise_M1_M4_AG2701X_AC2705X_Industry_Handbook_v2.pdf\">Download complete-solution handbook (Simplified Chinese PDF, V2.1)<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>These three products form the wired enterprise proposal. M1 and M4 meter the circuits; AG-2701X provides Ethernet access. Quantities follow the circuit plan. M1 \u00b7 Three-phase circuits Meter incomers and three-phase equipment with three external CTs. This proposal uses the RS485 variant. M4 \u00b7 Single-phase branches Meter lighting, sockets, rooms and single-phase equipment through one [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":144,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-145","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/pages\/145","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/comments?post=145"}],"version-history":[{"count":2,"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/pages\/145\/revisions"}],"predecessor-version":[{"id":181,"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/pages\/145\/revisions\/181"}],"up":[{"embeddable":true,"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/pages\/144"}],"wp:attachment":[{"href":"https:\/\/site.dcsmartmeter.com\/en\/wp-json\/wp\/v2\/media?parent=145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}